What is the measurement range / accuracy of MOCREO Sensors? =================================================================== Temperature Range and Accuracy ------------------------------------------------------------------ - MOCREO Sensor Temperature Range(Take Fahrenheit as an example) +-----------------------------+-------------------------------------+ |Sensor Type |Temperature measurement range | +=============================+=====================================+ |ST3 |-4° ~ 140° | +-----------------------------+-------------------------------------+ |ST4 |-40° ~ 221° | +-----------------------------+-------------------------------------+ |ST5 |-40° ~ 221° | +-----------------------------+-------------------------------------+ |ST6 |-4° ~ 140° | +-----------------------------+-------------------------------------+ |ST7 |-40° ~ 221° | +-----------------------------+-------------------------------------+ |ST8 |-40° ~ 221° | +-----------------------------+-------------------------------------+ |ST9 |-4° ~ 140° | +-----------------------------+-------------------------------------+ |ST10 |-328 ~ 392° | +-----------------------------+-------------------------------------+ MOCREO Sensor Temperature Accuracy ------------------------------------------------------------------ - ST4 / ST5 / ST7 / ST8 Sensor in different temperature ranges is as follows(Take Fahrenheit as an example): +-----------------------------+-------------------------------------+ |temperature range |Temperature measurement accuracy | +=============================+=====================================+ |14° ~ 185° |±0.9° | +-----------------------------+-------------------------------------+ |-4° ~ 14° |±1.8° | +-----------------------------+-------------------------------------+ |-22° ~ -4° |±2.7° | +-----------------------------+-------------------------------------+ - ST3 / ST6 / ST9 Sensor in different temperature ranges is as follows(Take Fahrenheit as an example): +-----------------------------+-------------------------------------+ |temperature range |Temperature measurement accuracy | +=============================+=====================================+ |-4° ~ 140° |±0.9° | +-----------------------------+-------------------------------------+ Humidity range and accuracy ------------------------------------------------------------------ - MOCREO Sensor measurement humidity range +-----------------------------+-----------------------------+ |Sensor Type |Humidity measuring range | +=============================+=============================+ |ST3 |0%~100%RH | +-----------------------------+-----------------------------+ |ST6 |0%~100%RH | +-----------------------------+-----------------------------+ |ST9 |0%~100%RH | +-----------------------------+-----------------------------+ - MOCREO Sensor humidity measurement accuracy: - When the ambient humidity is 0~80%RH, the difference in measurement values is ±2%RH. - When the ambient humidity is 80~100%RH, the difference in measurement values is ±3%RH.